Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
2.
Eur Urol ; 85(2): 139-145, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37914580

RESUMO

BACKGROUND: Periprostatic artificial urinary sphincter implantation (pAUSi) is a rare yet relevant indication for male neurogenic stress urinary incontinence (SUI). OBJECTIVE: To describe the surgical technique of robot-assisted pAUSi (RApAUSi) and compare the long-term functional results with the open pAUSi (OpAUSi). DESIGN, SETTING, AND PARTICIPANTS: Data of 65 consecutive men with neurogenic SUI undergoing pAUSi between 2000 and 2022 in a tertiary centre were collected retrospectively. SURGICAL PROCEDURE: Thirty-three patients underwent OpAUSi and 32 underwent RApAUSi. OpAUSi cases were performed by a single surgeon, experienced in functional urology and prosthetic surgery. RApAUSi cases were performed by the same surgeon together with a second surgeon, experienced in robotic surgery. MEASUREMENTS: Outcome measures were achievement of complete urinary continence, intra- and postoperative complications, and surgical revision-free survival (SRFS). RESULTS AND LIMITATIONS: RApAUSi showed superior results to OpAUSi in terms of median (interquartile range) operative time (RApAUSi: 170 [150-210] min vs OpAUSi: 245 [228-300] min; p < 0.001), estimated blood loss (RApAUSi: 20 [0-50] ml vs OpAUSi: 500 [350-700] ml; p < 0.001), and median length of hospital stay (LOS; RApAUSi: 5 [4-6] d vs OpAUSi: 11 [10-14] d; p < 0.001). Clavien-Dindo grade ≥3a complications occurred more frequently after OpAUSi (RApAUSi: 1/32 [3%] vs OpAUSi: 10/33 [30%]; p = 0.014). Achievement of complete urinary continence (zero pads) was comparable between the groups (RApAUSi: 24/32 [75%] vs OpAUSi: 24/33 [73%]; p = 0.500). The median follow-up periods were 118 (50-183) and 56 (25-84) mo for OpAUSi and RApAUSi, respectively (p < 0.001). A tendency towards longer SRFS was observed in the RApAUSi group (p = 0.076). The main study limitation was its retrospective nature. CONCLUSIONS: RApAUSi is an efficient alternative to OpAUSi, resulting in shorter operative times, less blood loss, fewer severe complications, and a shorter LOS with similar functional results and need for revision surgery. PATIENT SUMMARY: Compared with open periprostatic artificial urinary sphincter implantation (pAUSi), robot-assisted pAUSi leads to faster recovery and similar functional results, with fewer postoperative complications.


Assuntos
Robótica , Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Humanos , Masculino , Incontinência Urinária por Estresse/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Esfíncter Urinário Artificial/efeitos adversos , Procedimentos Cirúrgicos Urológicos/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Complicações Pós-Operatórias/etiologia
4.
Eur Urol Oncol ; 2023 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-37599199

RESUMO

BACKGROUND: Segmentation of three-dimensional (3D) transrectal ultrasound (TRUS) images is known to be challenging, and the clinician often lacks a reliable and easy-to-use indicator to assess its accuracy during the fusion magnetic resonance imaging (MRI)-targeted prostate biopsy procedure. OBJECTIVE: To assess the effect of the relative volume difference between 3D-TRUS and MRI segmentation on the outcome of a targeted biopsy. DESIGN, SETTING, AND PARTICIPANTS: All adult males who underwent an MRI-targeted prostate biopsy for clinically suspected prostate cancer between February 2012 and July 2021 were consecutively included. INTERVENTION: All patients underwent a fusion MRI-targeted prostate biopsy with a Koelis device. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Three-dimensional TRUS and MRI prostate volumes were calculated using 3D prostate models issued from the segmentations. The primary outcome was the relative segmentation volume difference (SVD) between transrectal ultrasound and MRI divided by the MRI volume (SVD = MRI volume - TRUS volume/MRI volume) and its correlation with clinically significant prostate cancer (eg, International Society of Urological Pathology [ISUP] ≥2) positiveness on targeted biopsy cores. RESULTS AND LIMITATIONS: Overall, 1721 patients underwent a targeted biopsy resulting in a total of 5593 targeted cores. The median relative SVD was significantly lower in patients diagnosed with clinically significant prostate cancer than in those with ISUP 0-1: (6.7% [interquartile range {IQR} -2.7, 13.6] vs 8.0% [IQR 3.3, 16.4], p < 0.01). A multivariate regression analysis showed that a relative SVD of >10% of the MRI volume was associated with a lower detection rate of clinically significant prostate cancer (odds ratio = 0.74 [95% confidence interval: 0.55-0.98]; p = 0.038). CONCLUSIONS: A relative SVD of >10% of the MRI segmented volume was associated with a lower detection rate of clinically significant prostate cancer on targeted biopsy cores. The relative SVD can be used as a per-procedure quality indicator of 3D-TRUS segmentation. PATIENT SUMMARY: A discrepancy of ≥10% between segmented magnetic resonance imaging and transrectal ultrasound volume is associated with a reduced ability to detect significant prostate cancer on targeted biopsy cores.

5.
Neurourol Urodyn ; 42(1): 80-89, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36183390

RESUMO

PURPOSE: The artificial urinary sphincter is the reference treatment for stress urinary incontinence in men, but it remains rarely used in women. This study aimed to compare long-term device survival between women and men, after the first implantation of an AMS800™ artificial urinary sphincter (Boston Scientific) for the treatment of a non-neurogenic stress urinary incontinence. MATERIALS AND METHODS: This retrospective cohort study included all patients with nonneurogenic stress urinary incontinence who underwent surgery in a large-volume university hospital between 2000 and 2013. The primary outcome was the overall survival of the device, defined as the absence of any repeated surgery (revision or explantation) during follow-up. Men and women were matched 3:1 according to age and year of implantation. Differences were analyzed using a Cox model accounting for matching and applying time intervals because hazards were not proportional over time. Sensitivity analyzes were performed, excluding firstly a population with a history of radiotherapy and secondly a population with more than one previous surgery for urinary incontinence. RESULTS: A total of 107 women were matched to 316 men. Median follow-up was 6.0 years (Q1-Q3 1.8-9.4): 7.0 years (Q1-Q3 3.1-10.3) for women and 5.1 years (Q1-Q3 1.3-9.1) for men. During the follow-up, 56 patients had an explantation of the device: 44 men (13.9%) and 12 women (11.2%), and 113 had a revision: 85 men (26.9%) and 28 women (26.1%). Men have a significantly higher risk of explantation or revision than women between 6 months and 8 years after implantation (hazard ratio 2.12 [1.29-3.48]). Before 6 months and after 8 years, there were no significant differences. Both sensitivity analyses found consistent results. CONCLUSIONS: This study suggests that device survival seems better in women after the first 6 months.


Assuntos
Incontinência Urinária por Estresse , Esfíncter Urinário Artificial , Masculino , Humanos , Feminino , Estudos Retrospectivos , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária por Estresse/etiologia , Resultado do Tratamento , Implantação de Prótese/efeitos adversos , Reoperação , Esfíncter Urinário Artificial/efeitos adversos
6.
World J Urol ; 40(7): 1661-1668, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35482073

RESUMO

PURPOSE: To perform a dynamic evaluation of the prostate cancer (PCa) detection rate according to the biopsy strategy over 10 years of practice in a single institution that pioneered MRI-targeted fusion biopsy (MRI-TB). METHODS: This stage 4 IDEAL study prospectively included all consecutive patients who underwent transrectal prostate biopsy for clinically suspected PCa between January 2010 and November 2020. Patients with positive MRI (PIRADS score ≥ 3) underwent both MRI-TB and systematic biopsy (SB) while those with negative MRI (PIRADS score < 3) underwent SB only. The main outcome was the evolution of the detection rate of clinically relevant PCa (csPCa; grade ≥ 2). The secondary outcome was the change in PCa detection rate according to the biopsy method. RESULTS: A total of 2942 men underwent prostate MRI and a prostate biopsy: 2322 underwent MRI-TB and 620 had SB only. The detection rate of csPCa increased 2.5-fold from 23 to 58%. The detection rate of PCa and csPCa was significantly higher in patients who underwent MRI-TB compared to those who underwent SB only (67% vs. 52% and 40% vs. 32%, respectively (P < 0.001 for both comparisons)). The number of csPCa diagnosed by MRI-TB increased linearly over the study period and represented the majority of PCa diagnoses after 2016. CONCLUSION: Implementation of MRI-TB in patients with positive MRI led to improved detection of csPCa.


Assuntos
Próstata , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia
7.
Urol Oncol ; 36(1): 11.e7-11.e12, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28993058

RESUMO

OBJECTIVE: To evaluate the pathological concordance rate of multiple synchronous renal masses (MSRM) presumed to be sporadic and to analyze predictive factors of concordance. MATERIAL AND METHODS: We identified from our institutional database patients with sporadic MSRM treated at our center between January 2000 and December 2015. All tumors were reviewed by a dedicated uropathologist. Pathological concordance rate was analyzed regarding clinical characteristics and preoperative imaging. RESULTS: We included 112 patients: 50 had unilateral synchronous renal masses and 62 bilateral synchronous renal masses. A total of 291 tumors were analyzed, with an average of 2.6 tumors per patient. Overall, the malignant concordance rate was 91.6%, the pathological concordance rate was 67.3% and the grade concordance rate was 62.5%. In univariate analysis, predictive factors of histological concordance were bilateral synchronous renal masses (odds ratio [OR] = 3.39; 95% CI: 1.06-10.8; P = 0.04), age<60 years (OR = 3.04; 95% CI: 1.2-7.7; P = 0.02) and ≥3 lesions (OR = 2.41; 95% CI: 1.03-5.68; P = 0.04). In multivariate analysis, age<60 remained significantly associated with histological concordance (OR = 3.84; 95% CI: 1.24-11.9; P = 0.02). CONCLUSIONS: The histological concordance rate of MSRM is low. Age at diagnosis <60 years, bilateral lesions and ≥3 tumors are predictive factors of histological concordance, but the pathological diagnosis remains difficult to predict. This heterogeneity is important to take into account, particularly when choosing the treatment upon the renal biopsy results from a single lesion.


Assuntos
Carcinoma de Células Renais/genética , Heterogeneidade Genética , Neoplasias Renais/genética , Neoplasias Renais/patologia , Carcinoma de Células Renais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Urol Oncol ; 35(2): 39.e9-39.e17, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28341496

RESUMO

OBJECTIVES: The complexity of partial nephrectomy (PN) is partly anticipated by morphometric tumor-based scores that do not consider patient-related issues such as adherent perinephric fat (APF). Also, the objective is to prospectively assess the predictive factors of APF during PN, its effect on complications, and to correlate it to the histological reality. METHODS: A total of 125 consecutive patients undergoing robotic or open PN were prospectively included. The Mayo adhesive probability score (MAP score) was compared to the peroperative presence of APF defined by a score≥2. Adipose tissue was analyzed histologically for fibrosis and inflammatory infiltrate of CD68+macrophages. Univariate and multivariate logistic regression analyses were performed to evaluate predictive factors of APF, and outcomes were compared using chi-square and Kruskal-Wallis tests. RESULTS: APF was present in 51 patients (40.8%) and associated with slight longer operating time and increased blood loss. Warm ischemia time, margins, transfusion, and the Clavien-Dindo score were not different. In multivariate analysis, only male sex, age, waist circumference, fat density on computed tomography, and MAP score were significant predictors of APF. A radioclinical score was more predictive of APF than MAP score alone. Histologically, there was no macrophage infiltration but larger adipocytes in APF without significant differences in fibrosis. CONCLUSIONS: APF can be accurately predicted using radioclinical data as the MAP score, combined with sex, age, and waist circumference. APF is associated with increased operative time and blood loss without postoperative complications. Histological analysis finds larger adipocytes in APF without inflammatory infiltrate, and no difference in fibrosis.


Assuntos
Tecido Adiposo/patologia , Rim/patologia , Rim/cirurgia , Nefrectomia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda Sanguínea Cirúrgica , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Análise Multivariada , Duração da Cirurgia , Estudos Prospectivos , Circunferência da Cintura , Adulto Jovem
9.
World J Urol ; 33(6): 787-92, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24985552

RESUMO

PURPOSE: Biopsy and final pathological Gleason score (GS) are inconstantly correlated with each other. The aim of the current study was to develop and validate a predictive score to screen patients diagnosed with a biopsy GS ≤ 6 prostate cancer (PCa) at risk of GS upgrading. METHODS: Clinical and pathological data of 1,179 patients managed with radical prostatectomy for a biopsy GS ≤ 6, clinical stage ≤ T2b and preoperative PSA ≤ 20 ng/ml PCa were collected. The population study was randomly split into a development (n = 822) and a validation (n = 357) cohort. A prognostic score was established using the independent factors related to GS upgrading identified in multivariate analysis. The cutoff value derived from the area under the receiver operating characteristic curve of the score. RESULTS: After RP, the rate of GS upgrading was 56.7%. In multivariate analysis, length of cancer per core > 5 mm (OR 2.938; p < 0.001), PSA level > 15 ng/ml (OR 2.365; p = 0.01), age > 70 (OR 1.746; p = 0.016), number of biopsy cores > 12 (OR 0.696; p = 0.041) and prostate weight > 50 g (OR 0.656; CI; p < 0.007) were independent predictive factors of GS upgrading. A score ranged between -4 and 12 with a cutoff value of 2 was established. In the development cohort, the accuracy of predictive score was 63.7% and the positive predictive value was 71.2%. Results were confirmed in the validation cohort. CONCLUSION: This predictive tool might be used to screen patients initially diagnosed with low-grade PCa but harboring occult high-grade disease.


Assuntos
Gradação de Tumores , Próstata/patologia , Neoplasias da Próstata/patologia , Fatores Etários , Idoso , Biópsia com Agulha de Grande Calibre , Estudos de Coortes , Humanos , Calicreínas/sangue , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estadiamento de Neoplasias , Tamanho do Órgão , Prognóstico , Próstata/cirurgia , Antígeno Prostático Específico/sangue , Prostatectomia , Neoplasias da Próstata/sangue , Neoplasias da Próstata/cirurgia , Curva ROC , Estudos Retrospectivos , Fatores de Risco
10.
J Urol ; 192(2): 483-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24603107

RESUMO

PURPOSE: Some patients fitted with an AMS 800™ type artificial urinary sphincter report urinary leaks in the sitting position whose mechanism remains unclear. In this experimental study we explain these residual leaks by characterizing fluid transfer and pressure variations in the device during cuff compression. MATERIALS AND METHODS: Two complete sets of AMS 800 devices were tested on an original test bench. A qualitative study using methylene blue dye was performed to assess fluid transfer within the device during manual cuff compression. After estimating the pressures exerted on the perineal floor in the sitting position, pressure variations in the AMS 800 components were measured in real time using the pressure sensors of a urodynamic workstation. RESULTS: When the AMS 800 cuff was compressed between 2 fingers, reflux of the blue dye into the balloon through the pump resistor was observed. After the cuff was compressed for 5, 10, 15 and 20 seconds at a pressure of 150 cm H2O, the minimal pressure measurements in the cuff were 37, 25, 14 and 12 cm H2O, respectively. Furthermore, the time required for cuff re-pressurization was 68, 87, 101 and 117 seconds, respectively. CONCLUSIONS: Urinary leaks reported in sitting position by patients fitted with an AMS 800 may be explained by compression of the urethral cuff between the pelvic floor and the chair, which causes emptying of the cuff into the balloon. Patients should be reassured that there is no implant dysfunction and may adopt simple lifestyle strategies to circumvent these leaks.


Assuntos
Complicações Pós-Operatórias/etiologia , Postura , Incontinência Urinária/etiologia , Esfíncter Urinário Artificial , Humanos , Masculino , Pressão , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...